eta-usa tel : 408-778-2793 fax : 408-779-2753 e-mail : sales@eta-usa.com derating curve efficiency curve 450 watt ac-dc converter wrp-sx series specifications wrp**sx-u 450watts/single input voltage input current input range input frequency input frequency range phase inrush current *1 efficiency [%] (typical) *2 80 82 84 85 85 85 86 86 model wrp05sx-u wrp06sx-u WRP12SX-U wrp15sx-u w rp24sx-u wrp30sx-u wrp36sx-u wrp48sx-u input characteristic ac115/230v 11a at ac115/6a at ac230 ac85-132v/170-264v(dc220-360v) 50/60hz 47-440hz single 12a(maximum) at ac115/24a(maximum) at ac230v
eta-usa tel : 408-778-2793 fax : 408-779-2753 e-mail : sales@eta-usa.com specifications wrp**sx-u 450watts/single output voltage [v] 5 6 12 15 24 30 36 48 output current [a] 90.0 75.0 40.0 32.0 20.0 16.0 13.0 10.0 voltage adjust range ripple and noise [mvp-p](maximum) *3 150 160 220 250 340 400 460 580 regulation a.statistic line regul ation [mv](maximum) 25 30 60 75 120 150 180 240 b.statistic load regulation [mv](maximum) 50 60 120 150 240 300 360 480 c.temperature coefficient *4 d.drift[mv](maximum) *5 40 45 75 90 135 165 195 255 e.dynamic load regulation [mv](typical) *6 f.recovery time *6 rise up time hold up time 94.5 78.8 42.0 33.6 21.0 16.8 13.7 10.5 5.5 6.6 13.2 16.5 26.4 33.0 39.6 52.8 remote sense remote on/off power fail detection parallel/series operation operating temperature *7 operating humidity storage temperature storage humidity isolation resistance vibration shock cooling ? leakage current ? line conducted noise ? weight (typical) ? mtbf [h] ? switching frequency[khz](typical) *5 for 7hour period after 1hour warm-up at 25 and rated input/output *6 when load changed from 25% to 75% of rated output current rapidly at ac115/230v input *7 safety approved at 25 *2 at dc260v input and rated output *3 measured by a bayonet probe at the end of a pair of 15cm long wires terminated with a 330uf electrolytic capacitor and a 100uf ceramic capacitor in parallel at a 0 to 100mhz bandwidth *4 at -5 to +50 2000g 155,000 135 *1 at cold start ? safety ul: ul1950 c-ul: csa c22.2 no.234 (level 5) 294m/s 2 forced air(fan installed) 1ma(maximum) at 25 ,rated input/output and rated input frequency built to meet fcc part15-b class a primary-secondary-frame ground 50m ? (minimum) by dc500v insulation tester 5-10hz:10mm double amp litude,10-55hz:19.6m/s 2 , 20minutes' period for 60minutes each along x,y,z axes(non-operating) 10 to 85%rh(non-condensing) withstanding voltage primary-secondary ac3,000v for 1minute primary-frame ground ac2,500v for 1minute secondary-frame ground ac500v for 1minute environmental -5 to +50 30 to 85%rh(non-condensing) -20 to +85 available available available available functions overcurrent protection R 105% of rated output current[a] current limiting with automatic recovery overvoltage protection R 110% of rated output voltage[v] output shutdown(to reset,leave 1minute after shut-off) not specified not specified 500ms(maximum) at 25 and rated input/output 20ms(minimum) at 25 and rated input/output output characteristic +/- 10% of rated output voltage(at no load within the input range) 0.03%/ model wrp05sx-u wrp06sx-u WRP12SX-U wrp15sx-u w rp24sx-u wrp30sx-u wrp36sx-u wrp48sx-u
eta-usa tel : 408-778-2793 fax : 408-779-2753 e-mail : sales@eta-usa.com dimension diagram
|